Problem Areas For Siding And Brick Wainscoting

Exterior Wall Transitions Flashing Between Wood Siding And Brick

Protecting a building envelope from moisture intrusion is one of the most fundamental aspects of structural longevity. When a structure features mixed exterior claddings, such as wood siding transitioning into a lower brick wainscot, the horizontal intersection between these two materials becomes a highly vulnerable area. Without proper flashing and water management strategies, these junctions can channel rainwater directly into the wall cavity, leading to extensive framing rot, mold proliferation, and compromised structural integrity.

The Danger Of Exposed Gaps Above Masonry

In many older buildings, or improperly detailed newer construction, a noticeable gap may exist between the bottom edge of the metal flashing and the top course of the brick wainscoting. If the wall assembly behind this cladding is not perfectly ventilated or is tightly sealed with interior drywall and insulation, this gap presents a severe risk. Wind-driven rain and runoff can easily blow up and under the flashing, entering the hollow cavity behind the brick. Over time, this recurring moisture saturates the concealed wood framing and sheathing, creating a hidden failure within the wall assembly.

The Proper Solution For Flashing Gaps

If a building is in the design or new construction phase, the ideal preventative measure is specifying a custom metal flashing with a downward vertical leg that extends sufficiently past the top course of the brick. This acts as a natural drip edge, safely shedding water away from the joint without relying on sealants. However, for existing buildings where the metal flashing falls short and leaves an exposed gap above the masonry, a strategic bead of high-quality exterior caulking is required. Applying caulk horizontally along the underside of the metal flashing where it meets the top of the brick will seal this void, blocking water from rolling backward into the masonry cavity.

The Fatal Flaw Where Never To Apply Caulk

While sealing the gap beneath the flashing is a sound remedial practice, applying caulk to the wrong side of the flashing will result in catastrophic wall failure. It is absolutely critical that the horizontal seam between the bottom edge of the wood siding and the top horizontal leg of the metal flashing remains entirely unsealed.

Modern building science dictates that exterior cladding is not completely waterproof. Moisture will inevitably find its way behind wood siding. To manage this, a protective water-resistive barrier, such as building paper or house wrap, is installed over the wall sheathing. This creates a drainage plane.

When water gets behind the siding, gravity pulls it down the face of the building paper until it hits the metal flashing, where it is directed outward safely. If this upper seam is caulked, the exit path is completely blocked. The trapped water will pool behind the siding, permanently soaking the wood sheathing and framing, ultimately destroying the wall from the inside out.

Essential Tips For Masonry And Siding Transitions

Specify an extended drip edge on metal flashing during new construction to overlap the masonry and eliminate the need for future caulking.

Seal the underside of existing short flashing where it meets the brick wainscoting to prevent wind-driven rain from entering the wall cavity.

Never caulk the gap between the bottom edge of the exterior siding and the top surface of the flashing, as this will trap draining moisture inside the wall.

Caulking Underneath Flashing On Brick Surfaces



When evaluating whether to apply caulking underneath flashing that overhangs a brick surface, the definitive answer based on building science and structural principles is no, you should generally never seal this bottom edge.

Applying caulking to the bottom overhang of flashing creates a moisture trap that directly violates the fundamental principles of water management in residential construction

.

Brick veneer is classified as a reservoir cladding. It is highly porous and absorbs water during rain events. Modern building codes, including the International Residential Code, require a one-inch minimum air space behind the brick and a weather-resistive barrier over the wall sheathing. When water penetrates the brick, gravity pulls it down the backside of the masonry to the flashing. The flashing is designed to intercept this water and direct it safely out to the exterior. If you caulk the bottom edge of the flashing to prevent wind-driven rain from blowing up underneath, you seal shut the exact exit path intended for internal moisture. This trapped water will accumulate, potentially rotting the underlying wood framing, deteriorating the steel lintels, and causing severe freeze-thaw damage or efflorescence in the masonry.

To combat wind-driven rain without trapping moisture, the construction industry relies on proper shingle-style lapping rather than sealants. The flashing should overhang the masonry by a sufficient distance to protect the joint. In areas prone to severe weather and extreme winds, a hemmed drip edge can be formed into the metal to disrupt surface tension and prevent capillary action. While the top edge of a counterflashing can and should be sealed against the brick face to prevent surface water from getting behind it, the bottom edge must always remain completely open to allow the wall cavity to breathe and drain.

Frequently Asked Questions About Masonry Flashing

To further expand your understanding of moisture management and structural defense systems, we have compiled a few additional insights regarding flashing applications.

Why Are Weep Holes Required In Brick Veneer Walls

According to the International Residential Code section R703.8.4, weep holes must be installed in the outside wythe of masonry walls at a maximum spacing of 33 inches on center. These weep holes must be located immediately above the flashing. The structural reasoning for this code is that since brick absorbs massive amounts of water, the cavity behind it operates as a drainage plane. Without weep holes to allow liquid water to escape and air to circulate, hydrostatic pressure and moisture buildup will compromise the structural integrity of the wall assembly and lead to extensive mold and rot within the home framing.

What Is Kickout Flashing And Where Is It Structurally Necessary

Kickout flashing, also known as diverter flashing, is required where the lower edge of a sloped roof intersects a vertical wall. Under IRC section R903.2.1, flashing must be installed to divert water away from where the eave meets the vertical wall. The reasoning is that large volumes of water rushing down the roof-to-wall intersection can easily overshoot the gutter and dump directly behind the siding or masonry veneer. A kickout flashing physically kicks the water away from the wall and out into the gutter system, preventing catastrophic water intrusion into the structural wall framing below.

How Far Should Through Wall Flashing Extend Past The Brick Face

Standard industry practice and guidelines from the Brick Industry Association dictate that through-wall flashing should extend slightly beyond the exterior face of the masonry, typically by about a quarter of an inch, and should be bent downward at a 45-degree angle to form a drip edge. The structural reasoning for this is surface tension. If the flashing is cut perfectly flush with the face of the brick to improve aesthetics, water flowing out of the wall can be drawn right back under the masonry by capillary action. Extending the flashing breaks that surface tension, forcing the water to drop cleanly away from the building.

Why Use Step Flashing Instead Of Continuous Flashing On A Sloped Roof Against Brick

When a sloped roof meets a vertical brick wall, IRC R905.2.8.3 requires the use of step flashing rather than a single continuous piece of metal flashing. The engineering reasoning behind this is that continuous L-flashing on a slope creates a single channel that can easily be overwhelmed by heavy runoff, forcing water up under the shingles. Step flashing integrates individual pieces of metal layered precisely with each course of roofing shingles. This overlapping ensures that any water bypassing one layer is immediately directed back on top of the next lower shingle, providing a redundant, gravity-driven water shedding system that does not rely on sealants.

Back To Siding

Our Favorite Construction Books
Stair Building Tutorials
Find Out How Do It Yourselfer’s Like You Can Become Great Stair Builders.
20x24 Garage And Loft
Learn How To Build A Variety of Different 2 Car Garages With Lofts.
Home Addition Projects
Do It Yourself Building Ideas for Small Budget One Story or Large Second Story Room Additions
Two Bedroom Home Build
Check Out This Small Home Building Project That A Small Family Like Yours Might Appreciate.
1923 Old Home Framing Project
Let’s Take A House Journey Back In Time To Learn More About Old House Construction.
434 Square Feet Home Building Project
Find Out How You Can Build This Small Cottage Style House or Backyard Granny Flat.
Two Story Open Floor Plan Project
Another Great Home Building Project That Could Provide Exactly What You Need in Your Next Home.
L Shaped Floor Plan Building Project
Check Out Our First Home Building Project To Get More Ideas About New House Construction.
Bathroom Remodeling
Check Out Our Helpful Videos Before Your Next Remodel to Avoid Making Dumb Mistakes.
Building Foundations
Learn How to Design and Build Foundations for A House or A House on The Side of a Hill.
Learn More About Decks
More Educational Deck BuildingTutorials That Save Time And Money.
Easy To Build Green House
This is One of The Easiest Green House or Shed You Can Possibly Build.
Framing Education
Learn More About Wall, Ceiling, Floor And Roof Framing.
Plumbing Repairs
Learn How To Fix Your Own House Plumbing.
Crawlspace Repairs
Watch Our Tutorials if You Need To Replace A Wood Beam or Sagging Floor Joist.
Framing Repairs
We've Got You Covered From Termites To Wood Rot And From Top To Bottom.